Permit: T08CM03233

Parcel: 141312440

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM03233

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/20/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
11/19/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) SHIM GABLE END AT BOTTOM CHORD TO DBL TOP CHORD
2) ADD DBL 2 X 6 HEADER AT 3 PT. BEARING AT DOOR
3) NEED RETRO P.A. AT REAR WALL
11/18/2008 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection :*
1) NOT FINISHED SHEATHING/FRAMING