Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
Permit Number - T08CM03217
Inspection Description - PLUMBING - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/09/2009 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
04/06/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* POST ADDRESS AND UNIT NUMBERS BOTH CLOSET FLANGES ARE TOO LOW IS 9 314.2 NIBCO FLANGE NOT LISTED FOR INSIDE 4" PIPE PROVIDE CORRECT SOLVENT WELD CONN. FAILURE TO COMPLY W/BASIC CODE REQUIREMENTS MAY RESULT IN REINSPECTION FEES |
|
03/02/2009 | PLUMBING - INTERMEDIATE | Partial Approval | IVRS - Inspection :* DWV WATER TEST THRU ROOF OK WATER DISTRIBUTION OK 1. NEED TO SEE CORRECT CLOSET FLANGE INSTALL |
|
02/27/2009 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* LEAK AT LAV CORRECT SIZING AT REVENT AND WATER TO TOILET ROOM PIPE SUPPORTS ON ABS |
|
02/24/2009 | PLUMBING - INTERMEDIATE | Not ready for Inspection | IVRS - Inspection :* |