Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/11/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
| 06/05/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* COMPLETE A DRY WALL FOR T&P TERMINATION, COMPLETE T&P DRAIN PIPING AND PROVIDE SUPPORT FOR RECIRCULATION PUMP. |
|
| 05/01/2009 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. SUPPORT ROOF TOP PIPING OFF ON ROOF 2. TEMPERATURE AND PRESSURE RELIEFS CANNOT BE COMBINED WITHOUT CORRECT UPSIZING OF PIPING AND SHALL GRAVITY DRAIN TO DAYLIGHT WITH NO OBSTRUCTIONS IN PIPING (KNICKS AND FLEX) EXPOSE TERMINATION OF T&P DEVICES. 3. PROVIDE COVER FOR ELECT. JUNCTION BOX 4. PROVIDE SUPPORT FOR EXPANSION TANK, PUMPS & PIPING |