Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/18/2009 | BUILDING - FINAL | Approved | APPEAL APPROVED FOR HARD-WIRED ALARM SYSTEM PER UL2017 | |
| 09/11/2009 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* 1) ALL OK 2) WAITING FOR APPEAL PAPERWORK |
|
| 07/23/2009 | BUILDING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) A CONDENSATE DRAIN MUST TERMINATE AT AN ABSORBENT SURFACE 2) NOTE: I WILL BE CHECKING WITH CITY BLDG OFFICIAL FOR A DETERMINATION REGARDING THE NEED FOR A POOL BARRIER |
|
| 07/14/2009 | BUILDING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) NEED COMB/RELIEF DUCTS FURNACE ROOM 2) NEED CONDENSATE PAN OVER FLOW PROTECTION (FURNACE) 3) REMOVE TAPE SINGLE TO DBL WALL FLUES (THREE SCREWS MIN.) 4) PLEASE LEAVE FIRE PLACE SPEC BOOK, GAS LINE PENETRATION AT FIRE BRICK REQUIRES FIRE PLACE CAULK, NOT FIRE CAULK 5) ARC FAULT REQUIRED FOR SMOKE DETECTOR CIRCUIT 6) FINISH ALL PLUMBING FIXTURES 7) ROMEX WIRE NUTED OUT OF WALL 8) NEED A LANDING (STOOP) AT SOUTH DOOR |