| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/23/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/20/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING P.A. 42 AT REAR WALL 2) PATIO BOX ? 15/DT1 BOLT PER PLAN NO RED HEADS 3) REMOVE SHIMS AT GARAGE, NOT 3 PT BEARING 4) DRIVE DOWN ALL STAPLES STICKING UP ABOVE ROOF DECK 5) SHEAR PANELS AT GARAGE APPROX 10' ONLY 6' NAILED TO ROOF |