| 10/31/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/16/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) BOX COL. REAR PORCH TWO BOLTS PER BEARING PLATE |
|
| 10/15/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) NO A03/A04E TRUSS IN TRUSS PACKAGE 2) NO LAYOUT SHEET FOR FULL LENGTH TRUSS PORCH 3) SAME PORCH NOT ON PRINT 4) PLAN WILL SHOW ALL PLATE ANCHORS HEADER SIZES |
|
| 10/13/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NAIL SHEAR PANELS TO ROOF 15/DT1 2) NAIL ALL STUDS CONNECTING SHEAR TO H.D./P.A. 3) NEED TRUSS DRAWINGS 4) COULDN'T FIND SHEET WITH DETAIL OF A PORCH WITH FULL LENGTH TRUSSES 5) MST48 STRAP AND BLOCKS GARAGE WING WALL 3/DT1 |