Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08CM03096
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/05/2009 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
03/04/2009 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection :* CORRECT LEAK AT HS TAILPIECE |
|
12/02/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. ABV. CEILING CORRECTIONS NOT COMPLETE 2. IDENTIFY ALL BACKFLOW DEVICES AND PROVIDE ANY SPECIFIED 3. CORRECT THE FOLLOWING HEALTH SAFETY CODE VIOLATIONS 4. HB VAC BREAKERS 5. AIR GAPS ON ALL INDIRECT WASTE PIPING SEPARATE CONDENSATE FROM DRAIN ON ICE MAKER AND PIPE PER MIN. CODE 6. MS VAC BREAKER W/DN STRM VALVE |
|
11/13/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* ABV CEILING STRAP CW CLOSE TO HAMMER ARRESTORS, OPEN VALVES FOR FINAL, COMPLETE ALL WORK LISTED ON PLANS ADDRESS ALL BACKFLOW PROTECTION REQUIREMENTS AS SPECIFIED ON NOTE #16 |