Permit: T08CM02990

Parcel: 11901076A


Addresses:

3372 S 6TH AV


Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Permit Number - T08CM02990

Inspection Description - EXCAVATION/LAYOUT REBAR & ZON

Inspection Status - Approved

Date Description Inspector Results Comments
04/16/2009 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
04/15/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
PRE-SLAB 2 SMALLER SLABS E OF LOADING DOCK 8" #4 18 O.C.
02/09/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
CANCELED BY CONTRACTOR
02/04/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. 3 - LOADING DOCK RETAINING WALLS
2. FOOTING NOT INSPECTED BY C.O.T
SPECIAL INSPECTED BY STERLING MADISON
NOTIFIED CONTRACTOR NOT ACCEPTABLE
01/20/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
01/15/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CERT SCREEN WALL FOOTING (7) S4.3
12/15/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
CONTINUOUS FOOTING @ D/5 TO 4 -- OK
12/11/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
15 F1 INTERIOR SPREAD FOOTING
4 MEZZ COLUMN FOOTING
12/10/2008 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1. 9 A1 TO B5; A1 TO A INCLUDING COLUMNS, 1-A TO D
ALL 4'8" TO 8'8"
2. TO BE SPECIAL INSPECTED
12/05/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1. EXTENSION TO SO FOOTING
RFI 22 & 25 DL - 5.5 TO 8.0
D0 - S.1 TO 5.5 NEW FOOTING
SPECIAL INSPECTED WESTERN TECH. REBAR & EPOXY
12/02/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
EAST WF2 FOOTING WITH RFI #'s 22 AND ONE DATED 11/19/08
11/26/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1.A-1 TO 5
WF1, F2, F3, F5 FOOTING
2. WF3 FOOTING
D-1 TO 4
3. TO PROVIDE SPECIAL INSPECTION
11/21/2008 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
RECEIVED $150.00 CHECK #6914 FROM HAYWARD BUILDERS

- LINE 9 OK
- LINE D1 FROM 5-9 OK
- LINE A1 FROM 5-9 OK AFTER SP. INSP. CONFIRMS BOTTOM MATT FOR NEW F2 & F4 FOOTINGS
- LOAD DOCK FOOTINGS SOUTH OF LINE D1 NOT INSTALLED DUE TO POSSIBLE DELETION