Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/26/2008 | FRAMING | Approved | IVRS - Inspection :* | |
| 11/25/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED TO INSULATE BEHIND TUB ENCLOSURE |
|
| 11/24/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 11/04/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999*. 1) NEED PROTECTION PLATE ON S/E CORNER FOR WIRES 2) INSULATE ROUND CONDUCTOR AT HOMERUN BUSHING INTO SERVICE PANEL 3) SEAL WITH CAULK ALL PROTRUSIONS (NAILS, STAPLES) THRU MOISTURE BARRIER AND OSB 4) PROTECTION PLATES NEEDED AT HALL BATH ANYTHING LESS THAN 1 1/2 NEEDS PROTECTION 5) NEED TO FIX BLOCK AT N/W CORNER (FIREBLOCK) 6) CIRCUIT WIRE FOR PENINSULA HAS A STAPLE AT HOLE IN STUD 7) NEED STUD SHOE ON OVERBORED HOLES, AT KITCHEN VENT |