Permit: T08CM02984

Parcel: 103217160

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/26/2008 FRAMING Approved IVRS - Inspection :*
11/25/2008 FRAMING Partial Approval IVRS - Inspection :*
1) NEED TO INSULATE BEHIND TUB ENCLOSURE
11/24/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
11/04/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*.
1) NEED PROTECTION PLATE ON S/E CORNER FOR WIRES
2) INSULATE ROUND CONDUCTOR AT HOMERUN BUSHING INTO SERVICE PANEL
3) SEAL WITH CAULK ALL PROTRUSIONS (NAILS, STAPLES) THRU MOISTURE BARRIER AND OSB
4) PROTECTION PLATES NEEDED AT HALL BATH ANYTHING LESS THAN 1 1/2 NEEDS PROTECTION
5) NEED TO FIX BLOCK AT N/W CORNER (FIREBLOCK)
6) CIRCUIT WIRE FOR PENINSULA HAS A STAPLE AT HOLE IN STUD
7) NEED STUD SHOE ON OVERBORED HOLES, AT KITCHEN VENT