Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 10/28/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) OK TO LATH 2) PROVIDE TRUSS DRAWING AT FRAMING INSPECTION |
|
| 10/15/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) NEED TRUSS CALCS 2) DRAWINGS SHOW ALL BRACED PANELS LAYING HORIZONTALLY-DRAWINGS LEAVE NO OPTION 3) MISSING A35 CLIPS ON ALL HEADERS 4) STOPPED INSPECTION |