Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM02983

Parcel: 103217130

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
11/21/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/28/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) OK TO LATH
2) PROVIDE TRUSS DRAWING AT FRAMING INSPECTION
10/15/2008 EXT METAL CLIPS/EXT SHEATHING Denied 1) NEED TRUSS CALCS
2) DRAWINGS SHOW ALL BRACED PANELS LAYING HORIZONTALLY-DRAWINGS LEAVE NO OPTION
3) MISSING A35 CLIPS ON ALL HEADERS
4) STOPPED INSPECTION