Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/25/2009 | FRAMING | Approved | IVRS - Inspection :* | |
| 06/24/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 1,2,5,6 & 8 NOT DONE, IF IT FAILS AGAIN THERE WILL BE A RE-FEE |
|
| 06/18/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BLOCK ALL DUCT BOOTS 3 SIDES 2) SHIM 2 X 12 BEAM TO BEARING WALL 3) NEED DWV TEST 4) NAIL PROTECT MASTER PEX-LAV AND SHOWER 5) REMOVE MESH STAPLES BEHIND HOME RUNS 6) ADD HANGER TO 2ND FLOOR STAIR PLATFORM FLOOR JOIST AND SHIM IT TIGHT 7) GROUND ALL METAL BOXES 8) SHIM BEARING/HEADER/TRIMMER CONNECTIONS 9) NAIL PROTECT 3" ABS AT RAFTER AND SUPPORT 3" VENT 90 DEGREE |
|
| 05/18/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 05/14/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* |