Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM02900

Parcel: 141312620

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM02900

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/21/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
10/20/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING GABLE END TRUSSES IN TRUSS DRAWING SET A11G
2) 20/SD4 FRONT BEDROOM WINDOW CS20 HORIZONTAL STRAPS AND BLOCKS
3) KIT TO DEN WALL, NAIL PANEL BLKS TO DBL TOP PLATE
4) GABLE END X BRACES NAIL TO VERT MEMBERS
5) ROOF NAILING TO MANY SHINNERS STICKING UP ABOVE ROOF DECK, STOPPED MARKING AT FRONT