Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM02899

Parcel: 141315810

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM02899

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/23/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/19/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1. FINISH INTERIOR SHEAR WALL AT GARAGE TO HOUSE
2. INSTALL OSB AT EAST, WEST WALLS GARAGE SHEAR, NEW PLAN #T08CM
3. ADD WIND BRACE AT WEST WALL TOTAL 3 BRACES
4. USE SHEAR TRANSFER TABLE ON DETAIL PAGE FOR # OF METAL CONNECTIONS REQ'D. TO CONNECT SHEAR WALL TO TRUSS BOTTOM CHORD
5. CHECK WITH POST TENSION ENG. CABLES NOT PULLED