Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM02899
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/23/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/19/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1. FINISH INTERIOR SHEAR WALL AT GARAGE TO HOUSE 2. INSTALL OSB AT EAST, WEST WALLS GARAGE SHEAR, NEW PLAN #T08CM 3. ADD WIND BRACE AT WEST WALL TOTAL 3 BRACES 4. USE SHEAR TRANSFER TABLE ON DETAIL PAGE FOR # OF METAL CONNECTIONS REQ'D. TO CONNECT SHEAR WALL TO TRUSS BOTTOM CHORD 5. CHECK WITH POST TENSION ENG. CABLES NOT PULLED |