Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM02883

Parcel: 129042220


Addresses:

242 S OLSEN AV


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T08CM02883

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
09/22/2008 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection :*
WAREHOUSE RESTROOMS OK
09/16/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
2" CAP AT OFFICE RESTROOM OK
OFFICE RESTROOM AREA UNDERGROUND OK

HAVE YELLOW PERMIT CARD ON SITE
THIS INSPECTION FOR 4" NEW SEWER FROM EXISTING 8" CLAY BACK TO CENTER WEST OF BLD. APP. 3' FROM BLD. WATER TEST IS OK.

TAP IS REQUIRE TO BE SAME DIAMETER AS 4" INSIDE DIAMETER OF PIPING. THIS WILL REQUIRE REINSPECTION.
PLAN SHOWS SEWER AS EXISTING HAVE PLAN REVISED AND CITY APPROVED AS NEW.

REINSPECTION OF TAP OF MAIN IS OK
09/15/2008 PLUMBING - ROUGH, SOIL Partial Approval IVRS - Inspection :*
RESTROOM WATER TEST THRU FOR UNDERGROUND ONLY TO EXISTING OK PIPE WRAPS OK

1. PROVIDE 2" PERMANENT CAP AT 2" PIPE AT TIE IN AREA ON EXISTING HAVE THIS ONLY INSPECTED PRIOR TO COVERING.