Inspection History: FRAMING

Permit Number - T08CM02845

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
10/09/2008 FRAMING Approved IVRS - Inspection :*
10/07/2008 FRAMING Partial Approval IVRS - Inspection :*
1) TWO DETAILS, FLR, JOISTS, PERPENDICULAR, PARALLEL SITUATIONS
2) PERPENDICULAR=PLAN DETAIL CALLS FOR 2 X 6 RIBBON AT TRUSS ENDS FOR BRACING, TRUSS WAS MADE FOR 2 X 4. PARALLEL=NO MENTION OF SHEAR TRANSFER AT SPACE BETWEEN FLOORS G-1 DRYWALL SHEAR BELOW
2) ADD STUD 2ND FLOOR SHOWER OVERNOTCHED
3) SUPPORT STAIR LANDING ONLY STUD ONE SIDE CUT
4) SHOWER BACKING VERTICAL
5) CUT NAIL PLATE FRONT BEDROOM MARKED ON FLOOR
6) NEED A FEW HANGERS RAFTER TO LEDGER FRONT ENTRY
7) INQUIRE WITH BLDG OFFICIAL FOR ENGR. PROBLEMS
8) GABLE END DETAIL REQUIRES, FLAT STUD RE-INFORCEMENT FOR STUDS OVER 6'-0" HT