Permit: T08CM02810

Parcel: 11931015A

Inspection Status: Denied

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
08/23/2010 BUILDING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) REFER TO T08CM00958
2) EXCEPT BEDROOM 2 CEMENT BOARD
3) LOWER CLEANOUTS TO GRADE
4) POST HOUSE NUMBERS
5) MISSING OUTLETS PER CODE ISLAND
6) SECURE DISHWASHER DRAIN HOSE HIGHEST POINT
7) SECURE LIQUID TIGHT 12" FROM DISCONNECT BOTH A/C
8) PROVIDE EXT. LIGHT FIXTURES EXIT DOORS
9) COMPLETE ALL DOOR STEPS OR STOOPS
10) PROVIDE ACCESS PANEL JACUZZI TUB MASTER
11) COMPLETE INTERIOR FIREPLACE
12) COMPLETE GRADING
13) VACUUM BREAKERS HOSE BIBS
14) SEAL MECH ROOM LID
15) HAMMER ARRESTORS LAUNDRY
07/29/2010 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) CANCELLED BY HANNAH