Permit: T08CM02787

Parcel: 141139430

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/25/2008 FRAMING Approved IVRS - Inspection :*
10/03/2008 FRAMING Partial Approval IVRS - Inspection :*
1) FILL ALL LUS 28 HANGERS/HOLES WITH SCREWS
2) HAVE OK FOR 4 LAGS 8" LONG X 1/2 DIAMETER AT HIP TO HOUSE CONNECTION 6 X 10 BEAM
3) 103
09/12/2008 FRAMING Partial Approval IVRS - Inspection :*
1) PLAN DOESN'T SHOW A CONNECTION HIP 6" X 10" BEAM TO HOUSE, OK 6" X 8" BEAMS TO POST
2) YOU USED #8 1 1/4" LATH SCREWS IN LUS 28 HANGERS WILL CHECK TO SEE IF THAT'S OK, ROOF DECK IS NOT COMPLETE