Permit: T08CM02771

Parcel: 122130210


Addresses:

1147 N COLUMBUS BL


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM02771

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/20/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
10/01/2008 PLUMBING - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*
1. REMOVE TEMP CAP AT EXT. CO AND INSTALL
THREADED ADAPTOR
2. HBS REQ. VAC BREAKERS
3. FS GRATE REQ. FS CLOGGED, OR NOT ABLE TO HANDLE DISCHARGE
4. FLOW CONTROL MUST BE RATED FOR THE FIXTURE UNITS DISCHARGED
5. OFFSET COPPER SO ONE WATER FLEX WILL WORK
LINKING FLEXES NOT ACCEPTABLE
6. SINK ELLS NEEDED AT PREP. SINK
7. DRAIN FOR PREP SINK, CLOGGED OR NOT ABLE TO HANDLE DISCHARGE
8. TRAP PRIMER REQ. UNION