Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T08CM02771
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/20/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* | |
10/01/2008 | PLUMBING - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1. REMOVE TEMP CAP AT EXT. CO AND INSTALL THREADED ADAPTOR 2. HBS REQ. VAC BREAKERS 3. FS GRATE REQ. FS CLOGGED, OR NOT ABLE TO HANDLE DISCHARGE 4. FLOW CONTROL MUST BE RATED FOR THE FIXTURE UNITS DISCHARGED 5. OFFSET COPPER SO ONE WATER FLEX WILL WORK LINKING FLEXES NOT ACCEPTABLE 6. SINK ELLS NEEDED AT PREP. SINK 7. DRAIN FOR PREP SINK, CLOGGED OR NOT ABLE TO HANDLE DISCHARGE 8. TRAP PRIMER REQ. UNION |