Permit: T08CM02654

Parcel: 14101008C


Addresses:

10770 E BILBY RD 01


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T08CM02654

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
05/14/2009 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
01/27/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
TOP CLASS 323
01/23/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ GRID LINES 28' EAST
OF A.0/2.3 TO 2.5, ROOM #323 PERIMETER WALLS AND INTERIOR WALLS @ ROOMS #313 & #314 FROM
4'8" TO 8'8" AFFE OK -- SPECIAL INSPECTION PERFORMED
01/22/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS REINFORCEMENT @ 28' EAST OF A.0/2.3 TO 2.5 AND PERIMETER WALLS OF ROOM #323 FROM 0' TO 4'8" AFFE
SPECIAL INSPECTION PERFORMED
12/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1) CMU WALL REINFORCEMENT STEEL AT GRID A.0/1.0 36' SOUTH 0'-36' EAST, EAST WALL ROOMS #302, 312 & 315 AND PERIMETER WALLS ROOMS #301, 313 AND 314 A.0/2.0 TO 4.0 36' SOUTH 8' TO TOP OUT A.0/1.0 TO 2.0 36' SOUTH, B.0/1 TO 4 37' NORTH 8' TO TOP OUT A1-A3/AA 28' WEST 8' TO 12' AFFE AND A.1 TO A.3/AA 28' EAST 8' TO 12' AND EAST WALL ROOMS #319 & 320 4' TO 8' AFFE-SPECIAL INSPECTION PERFORMED
12/24/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU STEEL REINFORCEMENT @ GRID LINES
A.01/1.0 0' TO 28' SOUTH, A TO B/1.0 31' WEST,
B.0 TO A.1/1.0 31' WEST FROM 12' TO TOP OUT &
A.1 TO A.3/1.0 31' WEST FROM 4' TO 8' AFFE - OK TO GROUT SPECIAL INSPECTED.
12/23/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
RAINED OUT
12/19/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS @ GRID LINES A.0/1.0 31'W/0' TO 27' SOUTH AND
31' W/0' TO 125' NORTH FROM 8' TO 12' -- A1 TO A2/AA 28' SE
A.0/1.0 28' SOUTH 10' TO 30' W AND 25' S/0' TO 90' E FROM 4'0" TO 8'0" - A.0/4.0 26' E 0' TO 64' NORTH & 26'E/0'
TO 25' S FROM 4' TO 8' - B.0/1.0 25' N/0' TO 106' EAST
FROM 4' TO 8' AFFE -- SPECIAL INSPECTED.
12/18/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
RAINED OUT -- CONTRACTOR CANCELED
12/17/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REINFORCEMENT @ GRID 31'W/0' TO 27' SOUTH OF A.0/1.0 AND 31' W/0' TO 125' NORTH OF A.0/1.0 FROM 4'0" TO 8'0" AND 28' SE OF A.1 TO A.2/A.A - 0' TO 4'0" AFFE
SPECIAL INSPECTION PERFORMED
12/16/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALL REBAR 0' TO 80' NORTH FROM S/W CORNER
FROM 4'0" TO 8'0" AFFE
12/10/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
CMU WALLS -- ALL PERIMETER WALL EXCEPT WALLS FOR ROOM #323 WALLS FOR INTERIOR ROOMS #301 & #313
FROM 0' TO 4'0" AFFE
12/09/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
12/08/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
RAINED OUT
12/04/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
12/03/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*