Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/17/2008 | PLUMBING - INTERMEDIATE | Approved | IVRS - Inspection :* | |
| 11/18/2008 | PLUMBING - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* CODE 1190 1. PLAN PROVIDED INDICATES REPLACEMENT OF EXISTING FIXTURES ONLY. PROVIDE A CITY APPROVED PLAN FOR NEW SINK PIPING; WASTE AND WATER. 2. MISSION COUPLINGS REQUIRED INSIDE BUILDING FOR TRANSITION TO CAST IRON 3. SINKS REQUIRE CLEANOUTS AND A SINK TRAP ARM IS TYPICALLY 1" 2" 4. WRAP PLASTIC PENETRATING CONCRETE W/FOAM 5. CONNECT/TEST WATER TUBING AND SLEEVE OR WRAP W/FOAM AT CONCRETE PENETRATION (POLY SLEEVING IS NOT SUFFICIENT) |