Permit: T08CM02647

Parcel: 12705001D


Addresses:

660 N SWAN RD

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
12/17/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
11/18/2008 PLUMBING - INTERMEDIATE Denied IVRS - Inspection :
See detailed listing on site.| 999*
CODE 1190

1. PLAN PROVIDED INDICATES REPLACEMENT OF EXISTING FIXTURES ONLY. PROVIDE A CITY APPROVED PLAN FOR NEW SINK PIPING; WASTE AND WATER.
2. MISSION COUPLINGS REQUIRED INSIDE BUILDING FOR TRANSITION TO CAST IRON
3. SINKS REQUIRE CLEANOUTS AND A SINK TRAP ARM IS TYPICALLY 1" 2"
4. WRAP PLASTIC PENETRATING CONCRETE W/FOAM
5. CONNECT/TEST WATER TUBING AND SLEEVE OR
WRAP W/FOAM AT CONCRETE PENETRATION
(POLY SLEEVING IS NOT SUFFICIENT)