Permit: T08CM02610

Parcel: 12003034C


Addresses:

1025 W DISTRICT ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
10/17/2008 FRAMING Approved IVRS - Inspection :*
10/13/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
10/10/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
1) COMPLETE ALL TRADES
2) OVERKNOTCHED 6 X 12 AT MASONRY ? POCKET MUST BEAR 1 1/2" MINIMUM.
3) MISSING CS20 STRAP PER PLAN
4) EXPOSE H2.5 CLIP AT 4 X 6 TO 6 X 12 CONNECTION
5) NAIL OSB AT HOLDOWNS TO TOP PLATE 6" ON CENTER
6) MISSING OSB CANNOT STRIP PER PLAN
7) STRAP BEAM AT CARPORT TO STORAGE ROOM EAST WALL