Inspection History Details
Inspection Status: Approved
Inspection History: SHEET ROCK NAILING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/06/2009 | SHEET ROCK NAILING | Approved | IVRS - Inspection :* | |
| 09/15/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) MECH ROOM OK TO TAPE FEEDS 2) FIRE CAULING AT PENETRATIONS |
|
| 09/09/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* POOL SIDE LOBBY/GREAT ROOM |
|
| 09/04/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) LOBBY AND ENTRY 1ST LAYER CEILING |
|
| 09/03/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1. 1ST LAYER CEILING MEN & WOMENS PUBLIC BATH, MAINTENANCE STORAGE, CORRIDOR AND SWEET SHOP 2. THEATER ROOM COMPLETE |
|
| 09/02/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) COMPLETE 166, COMMUNICATIONS, 161 2) KITCHEN CEILING 1ST LAYER, 147A, HOUSEKEEPING, ELEVATOR ROOM |
|
| 08/31/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) THEATER ROOM CEILING 1ST LAYER, 161, 166, COMMUNICATING ROOM 2) COMPLETE 169, 170, LAUNDRY OFFICE, 173, 175 AND 164 |
|
| 08/27/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 1ST LAYER CEILING ROOM: 164,169,170,173,175, OFFICE AND MANAGERS OFFICE |
|
| 08/18/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) ? STAIRWELLS OK |
|
| 08/12/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 1ST FLOOR GUEST ROOMS COMPLETE |
|
| 08/10/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) ALL GUEST ROOMS 1ST FLOOR ? CEILINGS OK |
|
| 08/04/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) GUEST ROOMS WEST OF ELEVATOR-OK 2) NEED FIRE STOP SYSTEM FOR CLEANOUTS IN FIRE WALLS |
|
| 07/31/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) ROOMS 100 THRU 108 COMPLETED |
|
| 07/30/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* REMAINING 1ST CEILING LID WEST OF LOBBY |
|
| 07/28/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) ROOM 100 TO 108 1ST FLOOR 1ST LAYER ON CEILING |
|
| 07/14/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR CORRIDORS AND UTILITY ROOMS, 2ND FLOOR COMPLETE |
|
| 07/10/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR 1ST LAYER ON CEILING IN COMMON ROOMS 2) ELEVATOR #2 EQUIPMENT ROOM COMPLETE 1ST FLOOR. ELVEATOR #1 EQUIPMENT ROOM COMPLETE 1ST FLOOR |
|
| 07/06/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR EAST OF ELEVATION SLEEPING ROOMS COMPLETE EXCEPT FOR #232 |
|
| 07/02/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR WEST OF ELEVATOR SUITES-OK |
|
| 06/30/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR EAST OF ELEVATOR 2ND LAYER ON ? |
|
| 06/29/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 2ND FLOOR FROM ELEVATOR WEST 1ST LAWYER BATHROOM LIDS 2) THIRD FLOOR CORRIDOR |
|
| 06/26/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 3RD FLOOR ROOMS COMPLETE |
|
| 06/25/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1. 3RD FLOOR EAST OF ELEVATOR 1ST LAYER BATH LIDS 2. 1ST & 2ND FLOOR STAIRWELL LIDS 2, 3, 4 |
|
| 06/19/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 210, 212 1ST LAYER CEILING AND 2ND FLOOR WEST OF ELEVATOR 1ST LAYER LIDS COMPLETE |
|
| 06/18/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) STAIRWELL #1 1ST LAYER LIDS 2) 1ST LAYER WEST OF ELEVATOR EXCEPT 210,212, AND 214 AND BATHROOMS |
|
| 06/15/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1. 310 TO 320 COMPLETE 2. SHEAR WALL ROOM 238 |
|
| 06/12/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* ROOMS 300 TO 308 COMPLETE |
|
| 06/11/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1. 3RD FLOOR BATH LIDS FROM ELEVATOR WEST 2. ELEVATOR 1 TO STAIRWELL 3 -- ALL UNITS EXCEPT BATHS 3. 1ST LAYER STAIRWELL 4 |
|
| 06/09/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1. EAST OF ELEVATOR 3RD FLOOR LID 1ST LAYER EXCEPT BATHROOMS 2. 1ST LAYER AROUND ELEVATOR 3RD FLOOR |
|
| 06/03/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) ELEVATION #1 1ST FLOOR 1ST LAYER, ROOM 315-320 ALL BUT BATHROOMS |
|
| 06/02/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* ROOMS 300 TO 319 EXCEPT BATHROOMS & 315 |
|
| 05/28/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1ST LAYER DRYWALL @ UNITS #300 THRU #320 EXCLUDING RESTROOMS, STAIRWALL 1ST LAYER ALL THREE FLOORS AND ELEVATOR SHAFT #2 -- 1ST FLOOR FIRST LAYER - OK |
|
| 05/21/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) ELEVATOR 2 1ST LAYER 2ND FLOOR OK 2) 3RD FLOOR CORRIDORS OK TO ROCK |
|
| 05/20/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1. 1ST LAYER STAIRWELL #1 WALLS 2. FIRST LAYER 2ND FLOOR ELEVATION #1 3. 1ST LAYER STAIRWELL #2 4. EAST WALL ELECTRIC ROOM |
|
| 05/18/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 3RD FLOOR 2ND LAYER ELEVATOR SHAFT |
|
| 05/15/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 3RD FLOOR ELEVATOR SHAFT 1ST LAYER OK |
|
| 05/13/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 1) 3RD FLOOR CORRIDOR CEILING OK TO TAPE |
|
| 05/06/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* REMAINING 3RD FLOOR TUB PRE-ROCK OK |
|
| 05/04/2009 | SHEET ROCK NAILING | Partial Approval | IVRS - Inspection :* 3RD FLOOR GREEN BOARD BEHIND TUBS OK |
|
| 04/30/2009 | SHEET ROCK NAILING | Not ready for Inspection | IVRS - Inspection :* |