Permit: T08CM02598

Parcel: 133231390

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T08CM02598

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
08/06/2009 PLUMBING - FINAL Approved IVRS - Inspection :*
08/05/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ONLY ONE ? NOT ALLOWED ON STREAM OF P TRAP: VERTICAL EXTENSIONS ARE NOT FOR USE ON TRAP ARM
2) EXPOSE CLEANOUTS
3) RUN TEST FIXTURES
4) CORRECTIONS AT WATER HEATER
08/04/2009 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) BEVERAGES AND BACKFLOW CERTS NOT COMPLETE
2) ? OF TRAP CANNOT BE BELOW POINT OF VENT
3) VENT FITTING AT 3 COMP SINK IS IN BACKWARDS
4) ALL FITTINGS SHALL BE INSTALLED IN CORRECT DIRECTION OF FLOW
5) EXPANSION TANK REQUIRES SUPPORT WHEN FLEX CONNECTION IS USED AT WATER HEATER
6) A FLEX MAY NOT BE USED ON T & P
7) A VACUUM RELIEF VALVE IS REQUIRED WHEN WATER HEATER IS ABOVE FIXTURES
8) PLUG FLOOR SINK NOT IN USE