Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/26/2009 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 03/16/2009 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* BATH LIGHT NEEDS A BOX - OUTLET HAS READINGS OF POWER |
|
| 03/03/2009 | ELECTRIC - FINAL | Denied | IVRS - Inspection : The wiring is not complete or does not comply with code.| 245* 1. CLEAN OR REPLACE DEVICES WITH EXCESS PAINT 110.12 2. BOXES MORE THAN 1/4" BOX TO SURFACE - 314.20 3. BATH LIGHT RECEPTACLE TO BE GFI PROTECTED 4. GROUND FIXTURE HARDWARE 5. KITCHEN COUNTER TOP RECEPTACLES TO BE GFCI PROTECTED 6. REVISE CIRCUIT DIRECTORY PER 408.4 7. EM LIGHTING TO BE ON CIRCUIT SERVED 700.12 (E) |