Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/19/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/15/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING ANCHOR BOLTS AT COLUMNS (PATIO) FRONT AND REAR 2) NORTH SIDE OF BLDG. HEADERS OVER WINDOWS NEED TO BE 3 1/2" WIDE NOT 3" |
|
| 09/12/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) BANG PLATES MISSING AT ABS PIPES AND ELECTRIC PVC 2) NAIL OSB/PLYWOOD TO BLOCK BETWEEN RAFTER/TRUSS THRU-OUT 3) UNABLE TO VERIFY COMPLIANCE AT REAR AND FRONT PORCH COLUMN WITH DETAIL 22/23 SD1 4) DBL 2 X 8 REQUIRED AT REAR PORCH SOUTH SIDE ON 4 X 4 POST ?? |
|
| 09/10/2008 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection :* 1) NOT READY PER SUPER |