Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM02544

Parcel: 116277190

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM02544

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
06/02/2009 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
05/28/2009 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) MISSING HOLDOWNS 2 EACH AT MASTER SOUTHWALL
2) MISSING HOLDOWNS AND SHEAR REAR PATIO COLUMN. STRAP BEAM AT REAR PORCH COLUMN
3) MISSING HOLDOWNS 2 EACH AT ENTRY
4) NAIL ALL OSB OR CDX AT HOLDOWNS DBL STUDS
5) MISSING CLIPS SP-9 THROUGHOUT