Permit: T08CM02529

Parcel: 14026678A

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM02529

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/16/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) SHIM 3 POINT BEARING AND ADD H2.5
09/05/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) SHIM 3 PT BEARING A08-A04 (OK TO LATH)
09/03/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) COMPLY WITH GABLE END DETAIL 2/SD1 16D NAILING 12" ON CENTER GABLE BOTTOM CORD TO WALL
2) MISSING A34 CLIP X BRACE GABLE END GREAT ROOM PER DETAIL 2/SD1
3) MISSING RAT RUN A04 TRUSSES BRACE 21
4) ROOF NAILING OK TO DRY IN
09/02/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ROOF NAILING NOT PER SHEAR TRANSFER PLAN
2) SHEAR PANEL BLK NOT FOLLOWED PER PLAN TOP BLK NEED TO BE SLANTED TO NAIL TO
3) GABLE END MISSING CLIPS
4) MISSING NAILING ON GABLE END PER PLAN
5) SHEET S-1 MISSING FOR HOLDOWN LAG ?