Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM02529
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/16/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* 1) SHIM 3 POINT BEARING AND ADD H2.5 |
|
09/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Partial Approval | IVRS - Inspection :* 1) SHIM 3 PT BEARING A08-A04 (OK TO LATH) |
|
09/03/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLY WITH GABLE END DETAIL 2/SD1 16D NAILING 12" ON CENTER GABLE BOTTOM CORD TO WALL 2) MISSING A34 CLIP X BRACE GABLE END GREAT ROOM PER DETAIL 2/SD1 3) MISSING RAT RUN A04 TRUSSES BRACE 21 4) ROOF NAILING OK TO DRY IN |
|
09/02/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) ROOF NAILING NOT PER SHEAR TRANSFER PLAN 2) SHEAR PANEL BLK NOT FOLLOWED PER PLAN TOP BLK NEED TO BE SLANTED TO NAIL TO 3) GABLE END MISSING CLIPS 4) MISSING NAILING ON GABLE END PER PLAN 5) SHEET S-1 MISSING FOR HOLDOWN LAG ? |