Permit: T08CM02527
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/08/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 09/05/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) WRONG SIZE HEADER PORCH SLIDING DOOR, 3 PT BEARING SHIM ALL 3 PT AT THAT LOCATION 2) A01EP TRUSS (SEE HASH MARKS FOR CONTINOUS BEARING, RELATING TO 2/SD1 |
|
| 09/03/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) MISSING P1 SHEARWALL KITCHEN NOOK SOUTH WALL 2) COMPLY WITH GABLE END DETAIL 2/SD1 TOE NAILING 12" ON CENTER AT GREAT ROOM AND CHECK RIDGE BOARD NAILING 2 (16D) EACH SIDE 3) MISSING SP-4 CLIP AT TOP PLATE REAR BEDROOM NORTH AT WINDOW KING STUD AND BOTTOM PLATE CHANNEL 4) MISSING RAN RUN A06 & A05 TRUSSES GARAGE 5) ROOF NAILING OK TO DRY IN |
|
| 09/02/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) SHEAR TRANSFER BLOCKING 2 BAYS SOUTH OF GARAGE, NEED TO BE LAYED FLAT TO CATCH OSB SHEAR 2) GABLE END NOT PER DETAIL 2/SD1-PUT CLIPS ON BOTTOM CORD OR BUILD PER PLAN 3) MISSING SHEET S-1 FOUNDATION PLAN TO VERIFY HOLDOWNS 4) MISSING A34 PER DETAIL 2/SD1 ON BRACING 5) NEED TO NAIL ROOF AT SHEAR PER DETAIL |