Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T08CM02518

Parcel: 140552130

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/02/2009 FRAMING Approved IVRS - Inspection :*
12/30/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PITCH ON T & P
2) A.B.'S MISSED AT GARAGE PLATE JOINT
3) A.B.'S MISSED AT #1 SHEARWALL GARAGE TO KITCHEN ALSO A.35'S AT TOP PLATE TO TRUSS, SHEAR TRANSFER CONNECTION
4) VERTICAL NAILER AT SHOWER FOR DRYWALL
5) LOAD SUPPORT FOR (STUD) INTERIOR BEARING 2,200 POUNDS FRONT GABLE TRUSS
6) DWV TEST
7) WILL CHECK ON VENT TO SANITARY TRAP COULD GO DRY