Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/02/2009 | FRAMING | Approved | IVRS - Inspection :* | |
| 12/30/2008 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) PITCH ON T & P 2) A.B.'S MISSED AT GARAGE PLATE JOINT 3) A.B.'S MISSED AT #1 SHEARWALL GARAGE TO KITCHEN ALSO A.35'S AT TOP PLATE TO TRUSS, SHEAR TRANSFER CONNECTION 4) VERTICAL NAILER AT SHOWER FOR DRYWALL 5) LOAD SUPPORT FOR (STUD) INTERIOR BEARING 2,200 POUNDS FRONT GABLE TRUSS 6) DWV TEST 7) WILL CHECK ON VENT TO SANITARY TRAP COULD GO DRY |