Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM02429
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/18/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
| 11/12/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) NEED TO ADD KING STUD FOR ? HOLDOWN AT SOUTH END OF GARAGE 2) NEED TO TIGHTEN ANCHOR BOLT AT SOLE PLATE SOUTHEAST CORNER 3) NAILS STICKING OUT OF SHEAR ON SOUTH SIDE OF 2ND FLOOR 4) RE-NAIL BOTTOM BRACE PANEL AT NORTH SIDE OF GARAGE 5) HTT16 NEED VERIFICATION OF 3RD PARTY INSPECTION-NO TRACE OF EPOXY AT HOLDOWNS 60 NEED MORE NAILS IN 2ND FLOOR SOLE PLATE IN 3 DIFFERENT LOCATIONS |