Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T08CM02426
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/19/2008 | PLUMBING - PROGRESS | Approved | IVRS - Inspection :* CLOSET FLANGE OK |
|
10/06/2008 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1. CWV IS LIMITED TO FLOOR SINKS OR FLOOR DRAINS, ABOVE GRADE TRAPS TO BE VENTED IN CONVENTIONAL MANNER 2. DOUBLE WYE MAY NOT BE INSTALLED IN HORIZONTAL POSITION 3. I.P.C DRAWINGS ARE HEAVILY ENGINEERED AND MUST BE INSTALLED EXACTLY PER PLAN 4. I.P.C AND U.P.C MAY NOT BE COMBINED OR INTERCHANGED 5. WILL REQUIRE A PETITION OF APPEAL ALLOWING I.P.C INSTALLATION |