Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/17/2008 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1. CORRECTIONS MADE OK 2. PLUMBING FINAL OK |
|
| 11/13/2008 | PLUMBING - FINAL | Cancelled | ||
| 11/13/2008 | PLUMBING - FINAL | Not ready for Inspection | 1. INDIRECT WASTE TERMINATION TO BE A MINIMUM OF ONE INCH ABOVE FLOOD RIM OF I.W RECEPTOR 2. USE APPROVED DRAINAGE MATERIALS FOR ESPRESSO DRAIN |
|
| 11/12/2008 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1. NO VACUUM RELIEF AT COLD INLET. SEE DELTA ONE REVISION 2. NO HEAT TRAPS AT WATER HEATER - SEE GENERAL PLUMBING NOTES #8 3. FINISH INSULATION ON HOT WATER PER GENERAL PLUMBING NOTE #6 4. SUPPORT EXPANSION TANK 5. INDIRECT WASTE REQUIRES MINIMUM 1" AIR GAP 6. ESPRESSO MACHINE REQUIRES BACKFLOW PROTECTION NO DRAIN FOR ESPRESSO MACHINE 7. CLOSET FLANGE TO EXTEND 14" ABOVE FINISHED FLOOR |