Permit: T08CM02417

Parcel: 141315340

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM02417

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/16/2008 FRAMING Approved IVRS - Inspection :*
09/10/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
FROM LAST INSPECTION:
1) NO BACKING VERTICAL 1ST FLOOR SHOWER
2) AT SHEAR TRANSFER TRUSS TO TOP OF SHEARWALL GAP IS TO BIG PROBLEM IS THE NAIL IS EXPOSED TO FAR WITHOUT ANY PENETRATION INTO WOOD IT HAS NO VALUE. FILL IN GAP WITH A FULL SIZE SPACER THEN NAIL
3) PLUMBING: 2ND FLOOR DBL LAV REQUIRES A 1 1/2" VTR, WASHER REQUIRES 1 1/2" VTR
4) WASHER DRAIN CANNOT BE IN THE BATHROOM GROUP
5) TWO FIXTURES THAT ARE UN-VENTED
09/08/2008 FRAMING Partial Approval IVRS - Inspection :*
1) MISSING VERTICAL BACKING 1ST FLOOR SHOWER
2) CALL IN STUCCO U-VALUE 00040
3) ALL 2ND FLOOR PLUMBING IN QUESTION
4) 2ND FLOOR SHEAR TRANSFER TOP PLATE OF SHEARWALL TO TRUSS BLOCKS SPACE IS TO LARGE, NEED TO SHIM
5) NEED IRC PLUMBING PLAN