Permit: T08CM02391

Parcel: 12701005D


Addresses:

5151 E BROADWAY BL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
01/12/2010 FRAMING Approved IVRS - Inspection :*
10/01/2009 FRAMING Partial Approval IVRS - Inspection :*
1) MAIN ENTRY CANOPY COMPLETE-OK TO COVER
09/29/2009 FRAMING Partial Approval IVRS - Inspection :*
1) MAIN ENTRY, CANOPY-NEED FRAMING AROUND STEEL BEAMS; ATTACH T-CHANNEL THROUGHOUT
09/25/2009 FRAMING Partial Approval IVRS - Inspection :*
1) CENTER PORTION (DOOR JAMBS) FRAMED AND IN PLACE (TUCSON COLLEGE-TI)
09/24/2009 FRAMING Partial Approval IVRS - Inspection :*
1) INFILL FRAMING OK
09/18/2009 FRAMING Partial Approval IVRS - Inspection :*
1) EAST PORTION IS COMPLETE JAMBS IN PLACE (TUCSON COLLEGE-TI)
09/16/2009 FRAMING Partial Approval IVRS - Inspection :*
CENTER PORTION (S & SW ROOMS & HALLWAYS)
09/15/2009 FRAMING Partial Approval IVRS - Inspection :*
1) (TUCSON COLLEGE-TI) NORTH WEST PORTION OF CENTER UNIT OK TO SHEETROCK
09/14/2009 FRAMING Partial Approval IVRS - Inspection :*
1) (TUCSON COLLEGE-TI) CENTER PORTION (NORTH HALF)-OK TO SHEETROCK PENDING PLUMBING FINAL
09/11/2009 FRAMING Partial Approval IVRS - Inspection :*
1) (TUCSON COLLEGE-TI) EAST PORTION (N & S); WEST PORTION (SOUTH HALF ONLY)
09/08/2009 FRAMING Partial Approval IVRS - Inspection :*
1) (TUCSON COLLEGE TI) EAST BLDG COMMON CORRIDOR TO EAST INTERIOR WALLS-OK TO SHEETROCK PENDING ELECTRIC AND PLUMBING INTERMEDIATES
2) PLEASE RED LINE TOILET LOCATION CHANGE IN ROOM #153
09/02/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
1) INFORMATION ONLY
08/18/2009 FRAMING Partial Approval IVRS - Inspection :*
1) EXTERIOR SOFFIT AND 8 COLUMNS LINE H/1-4 OK TO SHEETROCK PROGRESS AREAS
08/12/2009 FRAMING Partial Approval IVRS - Inspection :*
1) EAST WING SEPERATION WALL (CHANGE IN SPACE PLAN) LINES E-F/13.2 13.2-15; E-F/15
08/10/2009 FRAMING Not ready for Inspection IVRS - Inspection :*
08/07/2009 FRAMING Partial Approval IVRS - Inspection :*
1) FACADE EXTERIOR SOFFIT CLIPS-ALL AREAS EXCEPT LINE H/1.5-2-OK TO COVER PROGRESS AREAS DETAIL #2, PAGE A3.01
08/03/2009 FRAMING Partial Approval IVRS - Inspection :*
1) EXTERIOR SOFFIT FRAMING EAST WING-CENTER (TOWER) WEST WING EXCEPT AREA H/1-2