Permit: T08CM02391

Parcel: 12701005D


Addresses:

5151 E BROADWAY BL

Inspection Status: Approved

Inspection History: EXCAVATION/LAYOUT REBAR & ZON

Date Description Inspector Results Comments
01/12/2010 EXCAVATION/LAYOUT REBAR & ZON Approved IVRS - Inspection :*
09/22/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) WEST PORTION INTERIOR STEPS AS PER RFI (TUCSON COLLEGE-TI)
09/18/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) RAMP AS PER RFI DATED 9/04/09; OK TO POUR (TUCSON COLLEGE-TI)
09/16/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
09/15/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) (TUCSON COLLEGE-IT) INTERIOR RAMP, SOUTH LANDING-WEST PORTION (UP)
2) NORTH LANDING-RFI DATED 9/4/09
08/13/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) RETAINING WALL WEST WING AT LINE G.2-H/3
08/12/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) CANOPY (EXTERIOR) FOOTING/SLAB AT LINE4-5 OK TO POUR PROGRESS AREA
08/11/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) FOOTER FOR EXISTING SLAB (NEW RETAINING WALL) SK2, DATED 7/28/09-OK TO POUR FOOTING
08/10/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) NO ONE PRESENT AT SITE
08/06/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) EAST WING; SOUTH AND SOUTHWEST AT EAST PORTION
2) LINE: G-H; 13.2-14.5-OK TO POUR FOOTINGS
3) 1 COLUMN FOOTING C1/F1-WEST SECTION-COLUMN FOOTING #8 OK TO POUR
08/05/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) EAST WING-WEST AND SOUTHWEST PORTION: APPROX
08/03/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) SOUTHWEST CANOPY FOUDATION-6 EACH AT F1 COLUMN FOOTINGS-OK TO POUR PROGRESS AREAS
07/30/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
WEST WING (SOUTH & EAST EXTENSIONS)- EPOXY GROUTED DOWELS; DETAILS #101, 102 TO EXISTING SLAB
07/28/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) STUB TURN DOWN FOOTINGS-2 AT #5'S; LINE F/9.1-10.1-OK TO POUR
07/27/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) CONTRACTOR CANCELLED
07/23/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) SOUTH EXTERIOR SLAB AREAS-WEST WING DETAIL #104
07/21/2009 EXCAVATION/LAYOUT REBAR & ZON Partial Approval IVRS - Inspection :*
1) REINFORCEMENT STEEL AND EPOXY DOWELS AT NEEW SLAB AREA
2) SOUTH EXTERIOR POUR BACK AT SOUTH WING APPROX. 90 L.F.
3) SPECIAL INSPECTED BY PATTISON AND EVANOFF
07/20/2009 EXCAVATION/LAYOUT REBAR & ZON Not ready for Inspection IVRS - Inspection :*
1) NOT READY-PLEASE RECALL