Permit: T08CM02389

Parcel: 141340290

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM02389

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/30/2008 FRAMING Approved IVRS - Inspection :*
09/26/2008 FRAMING Not ready for Inspection IVRS - Inspection :*
1) STILL INSTALLING
2) ROOF NAIL NOT SIGNED OFF SHIM 3 PT TRUSSES WHERE REQUIRED. LEAVE TRUSS DRAWINGS ON SITE
3) CHECK NOTCHING OF REAR GABLE END TRUSS AT TOP CHORD
4) BACKING AT TUB SIDES
5) PROTECT CONDENSATE AT GARAGE SIDE
6) BANG PLATE PEX HALL BATH
7) BLOCK OSB AT REAR END OF SHEET NOT SUPPORTED
8) MISSING MECH PAGE IN PLAN SET, R-6 INSULATION DUCT (FLEX). WHERE DOES INSULATION GO ?
9) 3-16D IN BOTTOM OF EACH FRAMED SHEAR PANEL NAILED DOWN INTO DBL TOP PLATE