Permit: T08CM02363

Parcel: 105096750

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T08CM02363

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
09/29/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
09/24/2008 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SHEAR TRANSFER NAILING ON ROOF NEEDS TO BE 8D 6" ON CENTER
2) NEED TO ADD 2X STUD ON INTERIOR SHEARWALL AT DINING ROOM
3) CHANNEL NAILER AT STAIRWALL, NEEDS TO BE SOLID FOR 1 HR FIRE RATING OR 5/8 TYPE X HAS TO GO THRU