Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
Permit Number - T08CM02323
Inspection Description - ELECTRIC - INTERMEDIATE
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/10/2010 | ELECTRIC - INTERMEDIATE | Approved | IVRS - Inspection :* | |
02/05/2010 | ELECTRIC - INTERMEDIATE | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) CANNOT USE METALIC CABLE WITH PLASTIC BOXES 2) INSTALL NAIL PLATES ON CABLES WHERE BURIED HOLE IS LESS THAN 1 1/4" TO FACE OF STUD 3) REMOVED DAMAGED SWITCHES OF FIXTURES TO INSPECT WIRING IN BOXES TO SEE IF NEED TO BE REPLACED 4) HAVE APPROVED PLANS ON SITE 5) PANEL APPEARS TO BE DAMAGED AND NEEDS TO BE REPLACED |