Permit: T08CM02313

Parcel: 137055330

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Permit Number - T08CM02313

Inspection Description - PLUMBING - INTERMEDIATE

Inspection Status - Approved

Date Description Inspector Results Comments
10/08/2008 PLUMBING - INTERMEDIATE Approved IVRS - Inspection :*
09/30/2008 PLUMBING - INTERMEDIATE Partial Approval IVRS - Inspection :*
WATER TEST DWV IN WALL ONLY WITH WATER PIPING IN WALL ONLY.

1. PROVIDE OVERHEAD SUPPORT AT CORRECT INTERVALS ALL PIPING
2. PROVIDE REDLINE ON SITE FOR OVERHEAD VENT SYSTEM
3. INSTALL VENT FITTING OVERHEAD IN CORRECT DIRECTION AND RETEST
4. INSTALL LONG RADIUS FITTING AT P-2 HAND SINK
BY 3-COMP SINK