Permit: T08CM02276

Parcel: 135021170

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
09/25/2008 PLUMBING - FINAL Approved IVRS - Inspection :*
09/23/2008 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1. PROVIDE A PVC TRAP ADAPTOR FOR THE PVC DRAIN FOR HAND SINK. PVC PRIMER AND GLUE IS NOT APPROVED FOR PVC TO ABS PIPING CONNECTIONS.
2. PROVIDE CORRECT TRANSITION FOR PVC TO ABS PIPING AT BOTH AIR ADMITTANCE VALVES. GREEN GLUE IS NOT APPROVED FOR USE AT THIS LOCATION.
3. PROVIDE STRAINER AND GRATE FOR FLOOR SINK
4. PROVIDE ELECTRICAL CONNECTION FOR STOVE PER TAG ON STOVE ELECTRICAL WIRE CONDUIT WITH CORRECT JUNCTION BOX.