Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T08CM02269
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/26/2010 | PLUMBING - PROGRESS | Approved | ||
03/23/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
03/15/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
02/26/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) AM PIPING REQUIRE SAFETY PLATE WHEN WITHIN 1 1/4" OF STUD FACE PER LOCAL AMENDMENTS 2) 2" VENT UNDER 40' OK 3) SOLAR PIPING REQUIRES INSP PRIOR TO INSULATION, REMOVE ENOUGH TO VERIFY MATERIAL TYPE AND PROPER SOLDIER JOINTS 4) CHECK PLAN SPECS FOR INSULATION ? |
|
02/25/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* 1) ON 40' OF 2" VENT MAY RUN HORIZONTALLY 2) HORIZONTAL SECTIONS REQUIRE SUPPORT 3) WHERE THE WATER HEATER IS ELEVATED-SUPPLY DETAILS FOR SUPPORT DON'T FORGET VACUUM RELIEF VALVE |
|
02/24/2010 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection :* | |
02/23/2010 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection :* 1) UNDERFLOOR N/H DWV OK 2) UNDERFLOOR COPPER/INSULATED OK 3) 2ND FLOOR DWV THRU ROOF OK, INCLUDING WATER HEATER #1 4) 2ND FLOOR COPPER OK TO COVER |