Permit: T08CM02265

Parcel: 132091570

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T08CM02265

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
09/19/2008 FRAMING Approved IVRS - Inspection :*
09/17/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) ADD 3-2 X 10'S, 3-2 X 6 AND DBL 2 X 6 AND BRACE AS INDICATED
2) USE 2" GALV. NAILS 6" ON CENTER THRU-OUT
3) EXTENSION NEEDED AT GROUND WIRE USE 2" X 4" X 4" WITH SINGLE PLASTER RING AT 2 X 2 FURRED WALL
4) 2" METAL RISER AND WEATHER HEAD REQUIRED AT SERVICE PANEL
5) HOOK UP JACUZZI AND WATER TEST
6) CONNECTOR REQUIRED AT ALL GROUNDS
7) J-BOX IN CLOSET SHALL BE ACCESSIBLE
09/04/2008 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) WEEP-NEED HOLES FOR DRAINABLE STUCCO MESH
2) NO DWV OR WATER SUPPLY TEST
3) POOL/SPA NEEDS ACCESS OPENING TO MOTOR-ALSO PLANS CALL FOR SHOWER. NEED TO REVISE PLAN TO SHOW SPA AND GFI CIRCUIT
4) CLEARANCE TO FRONT OF TOILET DOESN'T HAVE MINIMUM CLEARANCE OF 21"
5) ALL MECHANICAL DUCT NEEDS TO BE STRAPPED FROM TRUSSES
6) NEED A.B. AT SOLE SPLICE UNDER WINDOW
08/28/2008 FRAMING Not ready for Inspection IVRS - Inspection :*