Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/03/2009 | FRAMING | Approved | IVRS - Inspection :* | |
| 03/27/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) COMPLETE PRIOR LIST ON 01/09/09 2) WINDOW NEEDED ABOVE TUB IN MASTER 3) MAKE UP BOXES, TIE GROUNDS TOGETHER PER CODE 4) BOX NEEDED FOR CIRCUIT AT FRONT DOOR 5) NAIL PROTECT PIPES PER #4 OF PREVIOUS INSPECTION 6) RETURN AIR TO FURNACE ? |
|
| 01/09/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) GAS PRESSURE TEST OK 2) WATER PLUMBING TEST OK 3) COMPLETE ALL FRAMING/ELECTRICAL 4) COMPLETE ALL PLUMBING, PROTECT WITH NAIL PLATES AND SUPPORT AQUA PEX AT 32" ON CENTER 5) USE PROPER NAIL PLATE AT DRYER VENT 6) COMPLETE HOME RUNS AT MAIN 7) COMPLETE FIREBLOCKING AT CEILING LEVELS |
|
| 01/06/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* | |
| 12/08/2008 | FRAMING | Not ready for Inspection | IVRS - Inspection :* |