Permit: T08CM02148

Parcel: 141093960


Addresses:

6400 E LACO WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/02/2008 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection :*
1) NAIL VERT STUDS AT HTT16'S
09/24/2008 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection :*
1) 6/3 REAR WALL 1ST FLOOR CALLS FOR RIM JOIST
2) IF YOUR USING THE REVISION DATED 8/20/08 CALL FOR 2 X 8 HEADER AT KIT.
3) BLK UNDER CUT OSB SCUPPER
4) TWO HTT16'S H.D.'S AT LIVING ROOM NOT TIGHT AGAINST STUD
5) MISSING WIND BRACING THRU OUT
6) 12/3 HEADER AT TOP OF STAIR ADD, HEADER TO SUPPORT STAIR
7) PORCH PLAN EXPIRED, DETAILS SHOW TWO LAGS AT BEAM JOINTS, NO DETAIL FOR 1 X DECK (REF CONNECTION RAFTER TO LEDGER) PLYWOOD WOULD USUALLY DO THAT
8) WALKED ROOF DECK-OK