Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/28/2008 | PLUMBING - ROUGH, SOIL | Approved | IVRS - Inspection :* DWV THRU TO EXISTING VENT OK WATER DISTRIBUTION OK INSULATION OK |
|
| 08/27/2008 | PLUMBING - ROUGH, SOIL | Denied | IVRS - Inspection : See detailed listing on site.| 999* |
|
| 08/22/2008 | PLUMBING - ROUGH, SOIL | Denied | 1. INSTALL LIKE FOR LIKE MATERIAL (C.I) 2. EXPOSE ALL PIPING, REMOVE ALL MOISTURE FROM DITCHES 3. INSTALL LONG RADIUS DRAINAGE FITTINGS 4. INSTALL PER APPROVED PLAN 5. COMPLETE PIPING TO POINT OF CONNECTION OR A RETEST WILL BE REQUIRED ON VENT SYSTEM TO POINT OF CONNECTION 6. CLOSET FLANGE WILL BE REQUIRED TO BE SITTING ON FINISH FLOOR MATERIAL AND BE SECURED TO FLOOR WITH INSPECTION PRIOR TO SETTING STOOL 7. WRAP ALL PIPING THRU CONCRETE POUR BACK 8. PROVIDE DIRECTIONAL FITTINGS FOR TEST FITTING |