Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
Permit Number - T08CM02104
Inspection Description - ELECTRIC - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/16/2008 | ELECTRIC - FINAL | Approved | RECEIVED CK#28779 - $225.00 | |
08/16/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* 1. SHEETMETAL SCREWS NOT ALLOWED FOR GROUNDING 2. PROTECT BULB IN CLOSET 3. CHECK SERVICE OK LIGHTS AND FANS TO CLOSE |
|
08/15/2008 | ELECTRIC - FINAL | Partial Approval | IVRS - Inspection :* |