Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T08CM02067
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/13/2008 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection :* | |
08/12/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) 6-2 X 6 POST STILL NEEDED EACH END OF GARAGE BEAM 2) NEED CLEAT NAILED ON LOWER ROOF TO SET UP LADDER TO 2ND STORY ROOF |
|
08/08/2008 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) OVERSPALLED HOLDOWN SOUTH WEST CORNER OF GARAGE AND SOUTH EAST CORNER 2) MIN 2 HTC4 CLIPS FOR MASTER BATH PER 511 DETAIL 3) HTC4 CLIPS MISSING PER 510 DETAIL 2ND FLOOR HALLWAY WALL 4) MISSING NAILING THROUGHOUT 5) NAIL VALLEYS PER 411 DETAIL 6) 6-2 X 6 POSTS NEEDED EACH END OF GARAGE BEAM 7) HVC 46 HVSC 26 HANGER NEEDED PER 334 DETAIL |