Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T08CM02046

Parcel: 12901036B


Addresses:

300 S TUCSON BL


Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T08CM02046

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
07/30/2009 PLUMBING - ROUGH, SOIL Approved EXCEPT FOR NOTE #1 FROM 07/10/2009 ALL OF CORRECTIONS MADE OK
OK TO COVER UNDERGROUND
07/10/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection 1) GAS NOT INSTALLED PER PLAN. PROVIDE ACCESS TO P.O.C. TO EXISTING AND HAVE RED LINES READY AT TIME OF INSPECTION
2) CONNECTIONS TO EXISTING SEWER ARE COVERED. MUDDY SOILS INDICATE A LEAK
3) 3" ABS MAY NOT EXTEND UPSTREAM OF THE 3" FLOOR CLEANOUT WITHOUT AN ADDITIONAL FULL SIZE CLEANOUT
4) WATER PIPING NOT INSTALLED PER PLAN. PLAN CALLS FOR TYPE "L" COPPER
5) ALL CHANGES TO THE PLAN REQUIRE AT LEAST RED LINES TO BE AVAILABLE AT THE TIME OF THE INSPECTION
07/09/2009 PLUMBING - ROUGH, SOIL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE APPROVED PLANS, CORRECT SIZING
2) INSTALL ABV SLAB TEST FITTINGS OR PLAN TO RE-TEST
3) REMOVE ROCKS