Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T08CM02020
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/10/2012 | FRAMING | Approved | ||
| 08/20/2012 | FRAMING | Partial Approval | DISPLAY PONY WALLS AT REAR OF SALES FLOOR OK ELECTRICAL AT SAME OK | |
| 07/24/2012 | FRAMING | Partial Approval | IVRS - Inspection :* 1) PROVIDE X BRACE ON WALLS NOT TO DECK EXCLUDE HARDLIDS 2) TEST DWV 3) TEST SEWER DRAINS, EXPOSE DRAINS AT BOTTOM |
|
| 07/23/2012 | FRAMING | Not ready for Inspection | IVRS - Inspection :* CUSTOMER CANCELLED |
|
| 07/02/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) ADD STEEL SUPPORT TO ELECTRIC FREE STANDING WALL 2) SPRINKLER ROOM WALLS |
|
| 06/18/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) MONEY ROOM, HOLDING ROOM KIDS PLAY AREA NEEDS BACKING IN RESTROOM INTERIOR COLUMNS OK |
|
| 06/10/2010 | FRAMING | Partial Approval | IVRS - Inspection :* 1) OFFICES IN S.W. CORNER AREA 4 NEEDS BRACING TO DECK |
|
| 05/08/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 3 SOFFIT INFILLS NEXT TO EL SUPER |
|
| 05/06/2009 | FRAMING | Partial Approval | IVRS - Inspection :* EAST FURR-OUT WALL OK |
|
| 04/24/2009 | FRAMING | Partial Approval | IVRS - Inspection :* METAL STUD FURROUT @ GRID LINES A TO K/1 -- 1 TO 7/K - 7 TO 6/E.5 TO K AND 6 TO 5/E.5 TO A & 5 TO 1/A @ INTERIOR |
|
| 04/23/2009 | FRAMING | Not ready for Inspection | IVRS - Inspection :* 1) MISSING LOWER SCREWS TO TRACK ON EXT. FURR OUT |
|
| 03/18/2009 | FRAMING | Partial Approval | IVRS - Inspection :* BACK SIDE OF STORE FRONTS OK TO SHEATH WITH RFI OK 2 SLATED DEFLECTOR CLIP |
|
| 03/13/2009 | FRAMING | Denied | IVRS - Inspection : See detailed listing on site.| 999* DEFLECTOR CLIP DETAIL S1.9 (2) 4 - #10 SCREWS WITH WASHERS |
|
| 02/09/2009 | FRAMING | Partial Approval | IVRS - Inspection :* OK TO PROGRESS WORKING ON UPPER STOREFRONTS |
|
| 02/03/2009 | FRAMING | Partial Approval | IVRS - Inspection :* WORKING ON S,W,N UPPER STORE FRONTS |
|
| 01/21/2009 | FRAMING | Partial Approval | IVRS - Inspection :* EAST STORE FRONT ALL BUT INTERIOR DIAGONAL BRACING |
|
| 01/15/2009 | FRAMING | Partial Approval | IVRS - Inspection :* EAST STORE FRONT |
|
| 01/09/2009 | FRAMING | Partial Approval | IVRS - Inspection :* ADDED 01025 EXT. CLIPS & SHEATHING |
|
| 01/08/2009 | FRAMING | Partial Approval | IVRS - Inspection :* 1. WEST AND NORTH EXTERIOR SIGN PARAPETS 2. WELD CLIPS SPECIAL INSPECTED BY SPEEDIE |
|
| 12/22/2008 | FRAMING | Partial Approval | IVRS - Inspection :* WORKING ON UPPER EXTERIOR CANOPY OK TO PROCEED |
|
| 12/19/2008 | FRAMING | Partial Approval | IVRS - Inspection :* OK TO PROCEED WORKING ON STORE FRONTS |
|
| 12/03/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 1. OK TO PLYWOOD RADIUS WALL WITH TRADE OK 2. FIND OUT HEIGHT OF PLYWOOD 3. WAREHOUSE INTERIM WALL 1HR FIRE RATED |
|
| 11/21/2008 | FRAMING | Partial Approval | IVRS - Inspection :* 6" DECK @ D/4 CENTER OF BUILDING OK TO COVER |
|
| 11/17/2008 | FRAMING | Partial Approval | IVRS - Inspection :* SOUTH SIDE CORNICE @ ROOF LEVEL -- SHEATHING OK TO STUCCO MESH |
|
| 11/14/2008 | FRAMING | Partial Approval | IVRS - Inspection :* SOUTH WALL AND NORTH WALL PARAPET CANOPY OK TO SHEATH |
|
| 11/13/2008 | FRAMING | Partial Approval | IVRS - Inspection :* SE PARAPET CANOPY OK TO SHEATH 1 S4.2 |
|
| 11/12/2008 | FRAMING | Partial Approval | IVRS - Inspection :* PARAPET OVERHANG 1-K TO F 5 S4.2 12 S1.8 |