Permit: T08CM02020

Parcel: 11901051L


Addresses:

295 W 40TH ST


Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T08CM02020

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
04/14/2009 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection :*
1) LAST OF DUMPSTER WALLS
04/06/2009 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. DUMPSTER S.W. CORNER OF EXISTING BLDG.
2. S.W. LOADING DOCK WALL
3. 2 SO DUMPSTER ENCLOSURES
11/04/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. TOP OUT OF MAIN BLDG. OK
2. NEED RFI FOR EPOXY OF MISSED LEDGER BOLTS
11/03/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
10/31/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. 1-A TO B 20' TO 24'
2. 1-B TO D TO 28'4" TO PORT
3. A-1 TO 3 TO 24'8"
4. 7-G TO H TO 32
5. K-2.5 TO 3 AND 4.5 TO 5.5 TO 28'4"
10/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. A-1 TO 4
1 - A TO B TO 20'
1 - B TO D TO 24'
2. NEEDS SPECIAL INSPECTION
10/29/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
ALL PROGRESS @ NW AREA OK
10/28/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. C TO A -- 12' TO 16'
2. A 1 TO 3.5 TO 12'8"
3. 7-B TO D TOP OUT 28'4" DOUBLE #6
4. 7-E TO G TO 28'8"
5. NEEDS SPECIAL INSPECTION
10/27/2008 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection :*
MIN. 42" LAP FOR #7 REBAR
10/26/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
SOUTH WALL TO 24'8" EAST OF DEPRESSION
WEST WALL A-7 TO 3 TO 24'8"
A-3 TO 1 TO 8'
10/23/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
K-2.6 TO 3.2
K-4.6 TO 5.2 20 TO 24
7-G TO K TO 28'4"
A-7 TO 3 20'8"
10/22/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. 1-A TO D TO 8'
A-3 TO 7 TO 16'8"
A-2 TO 3 1ST LIFT PILASTERS
1-D TO F TO 20'

2. SPEEDIE SPECIAL INSPECTED
10/21/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
7-A TO D 16' 2'
A-3 TO 7 8' TO 12'
10/20/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
7-G TO K 20'8" TO 24'8"
A-7 TO 3 4'8" TO 8'8"
7-D TO A 12'8" TO 16'8"
10/17/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1 - H TO K 28'4" AFF (TOPOUT)
1 - D TO F 20'8" AFF
7 - H.5 TO K TO 24'8" ROOF LINE

NEED STAMPED ENGINEERED APPROVAL FOR CONTROL JOINT LOCATIONS
10/16/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
7-A TO D 8'8" TO 12'8"
1 - A TO C TO 4'8"
7 - H.5 TO K 24'8"
10/14/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
7 - A TO D
4'8" TO 8'8"
1 - A TO D 12'8" TO 16'5"
10/13/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1 K TO D 4TH LIFT ADDING #7 JAMB BARS
10/10/2008 REINFORCED MASONRY PRE-GROUT Partial Approval 20'8" SOUTH WALL K-D; 5' SOUTH & WEST LINE A 3-5
5' LINE K A-D
10/09/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. K-1 TO 3, K-4.5 TO 7, 7-D TO K, 1-E TO K TO 16' AFF
2. 1-C TO E 8'11" AFF ADD MISSING JAMB BARS
3. SPEEDIE SPECIAL INSPECTED
10/08/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
3RD LIFT K-1 TO 3 1-K TO D
10/07/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
3RD LIFT
N. LOADING DOCK RAMP
WALL OK TO CLOSE

7 - O TO K

NEEDS SPECIAL INSPECTION
10/06/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. 2ND LIFT 1 - K TO D
K - 1 TO 3 (4) S1.4
SCHEDULE S1.1

SPEEDIE SPECIAL INSPECTED
10/03/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. 2ND LIFT 7 - K TO D
K 4.6 TO 7
2. ALL JAMB BARS ARE #7
3. MIN.LAP #5 BAR 30"
10/02/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1ST LIFT LINE 1 -- K TO D
TO BE SPECIAL INSPECTED
10/01/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. ALL JAMB BARS #7
2. FIRST LIFT 5' AFF
K- 1 TO 3
7 - D TO 6
1 - K TO F
3. STEM WALL REMAINING WEST 2/3 OF N.WALL
09/30/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. K TO 6 1ST LIFT INSTALL CORRECT JAMB BARS
2. STEM WALL K-1 TO 4 1-K TO E
09/29/2008 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection :*
1. LINE 7 - K TO B --- STEM WALL
2. WHERE BOND BEAM IS INTERRUPTED FOR ROOF DRAINS A BOND BEAM WILL BE POURED ABOVE SLEEVES
3. TO BE SPECIAL INSPECTED